Description

Having a high communication speed, the Interface Converters by GIC offer a cost-effective solution to a smooth interworking between different communication interfaces.

  • Compatible with USB 2.0
  • Input: USB 2.0 Protocol
  • Output: RS232 on DB9 Male connector compatible to PC RS485/RS422 on terminal block.
  • Communication Speed: 300bps to 230Kbps.
  • Auto direction control for RS485-2W data transmission.
  • Cable: USB 2.0 type A to type B cable.
  • Galvanic Isolation of 1.5kV
  • RS232/RS485 line protection: +/- 15kV ESD.
  • LED Indication for Transmit Receive signals.
  • Input power from USB port, no external power required.
  • 2M enclosure with DIN Rail mounting.
  • Virtual COM port USB Drivers provided for Win XP, Vista, Win7, Win8


Specifications

Parameters


USB

Version: USB Specification 2.0 compliant

Speed: 12 Mbps


Isolated Serial Interface

RS 232: TX, RX,GND

RS 485: D+, D-, GND

RS 422: TX+, TX-, RX+, RX-, GND


Auto direction control for RS485-2W

Serial line protection: Internal 15kV ESD protection

Isolation: 1500 V Galvanic Isolation

Connector: RS232 - D Type 9 Pin Male Compatible with PC, RS485, RS422- Screw Terminals

LED indication: TX, RX, Communication Mode Indication.

Power requirements: USB BUS Powered

Operating temperature: 0° C To + 60° C

Storage temperature: -20° C To + 70° C

Humidity: 5% (Rh) to 95% (Rh)

Enclosure: Flame Retardant UL94-V0

Dimension (W x H x D): 36 X 90 X 52.3 mm

Weight (unpacked) Approx.: 100 g

Pollution degree: II

Mounting: Base / DIN rail

Degree of protection: IP 20 for Terminals, IP 40 for Enclosure


Certification / Standard

EMI / EMC

  • Harmonic Current Emissions IEC 61000-3-2
  • ESD IEC 61000-4-2
  • Radiated Susceptibility IEC 61000-4-3
  • Electrical Fast Transients IEC 61000-4-4
  • Surges IEC 61000-4-5
  • Conducted Susceptibility IEC 61000-4-6
  • Conducted Emission CISPR 14-1
  • Radiated Emission CISPR 14-1


Environmental

  • Cold Heat IEC 60068-2-1
  • Dry Heat IEC 60068-2-2
  • Vibration IEC 60068-2-6
  • Repetitive Shock IEC 60068-2-27
  • Non-Repetitive Shock IEC 60068-2-27