Citel DS50PVS-600/51 SPD, PV, type 2, 600VDC, 15kA

Citel
480471
768 In stock
ENERGY : Solar PV Balance Of System
DS50PV/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. Based on the use of specific varistors, providing a protection in common mode or common and differential mode. DS50PV/51 surge protectors use varistors as the primary protective element. Varistors are devices...

DS50PV/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. Based on the use of specific varistors, providing a protection in common mode or common and differential mode.

DS50PV/51 surge protectors use varistors as the primary protective element. Varistors are devices that have a nonlinear resistance that decreases as the applied voltage increases. This characteristic makes them ideal for use in surge protectors, as they can effectively shunt high voltage surges to ground and protect sensitive equipment.

The DS50PV/51 surge protectors also feature a compact and robust design, making them well-suited for use in harsh outdoor environments. They have a high discharge capacity and are designed to be installed in series with the DC power supply, providing protection for PV systems against transient overvoltages.

Overall, DS50PV/51 surge protectors are a reliable and effective solution for protecting photovoltaic power supply networks against lightning surge voltages. Their use of specific varistors provides both common mode and differential mode protection, making them suitable for a wide range of PV system configurations.

Features

  • Type 2 surge protector for Photovoltaic
  • PV voltage: 600V DC
  • In: 15 kA
  • Imax: 40 kA
  • Pluggable module
  • Remote signaling included
  • UTE C61-740-51, EN 50539-11 compliance
Rubicon Sustainable Technology Applications

Citel DS50PVS-600/51 SPD is utilized in the following areas:

  • Residential
  • Small Commercial (0 - 50kW)

SPD type 2

Network  PV network 600V DC

Nominal PV voltage  600V DC

Max. PV operating voltage Max. PV operating voltage

Residual Current  < 0.1 mA

PV Permanent Operating current  < 0.1 mA

Follow current   None

Nominal discharge current  15 kA

Max. discharge current  40 kA

Total Maximum discharge current  60 kA 

Current withstand short circuit PV  15000 A

Connection mode(s)  +/-/PE

Protection mode(s)  Common mode

Protection level +/PE (-/PE)  2.8 kV

Citel DS50PVS-600/51 SPD, PV, type 2, 600VDC, 15kA